CC-ID Tool

Guides › Back up before you code

Guide · Updated 23 November 2026

Back up before you code

A backup turns a coding mistake into a five-minute fix. Here's what to save in BimmerCode and in E-Sys, and how to use it to go back.

What a backup is

Each module's coding is a block of bytes. E-Sys saves it as an NCD file (net coding data), and BimmerCode keeps its own copy on your phone. With a copy of the bytes from before your change, you can always write them back.

In BimmerCode

In E-Sys

  1. Save the vehicle order. Read the FA (vehicle order) and save it with the date in the file name before you activate or change anything.
  2. Read the module's coding. Right-click the module's CAFD and choose Read Coding Data. E-Sys saves the result as an NCD file in the CAF folder of its data directory, often C:\ESysData\CAF. The folder can differ on your installation.
  3. Copy it somewhere safe. The NCD file is named after the CAFD, for example CAFD_00000069_009_001_006.ncd. Reading the same module again later overwrites it, so copy it to a folder outside E-Sys with the car and the date in the folder name.
  4. Write down what you change: module, CAFD, parameter, original value and new value. A short log is often the quickest way back.

Going back

After a dealer update

A software update can give a module a new coding file version, the numbers at the end of the CAFD name. E-Sys only codes an FDL with the exact coding file it came from, so a backup from before the update may not fit. Read and save fresh backups after every update, and note the CAFD version with each one.

A simple coding log

Keep one row per change. An example:

DateModuleCAFDParameterOriginalNewResult
23 Nov 2026KOMBI00000069_009_001_006CC_AKTIVIERUNG_1, byte 4FFBFWrong key message gone